Lina Abdullah Alshahrani, LI Xi, 南俊民, 谭娟娟, 顾凤龙. 修饰玻碳电极对多巴胺和尿酸的电化学检测(英文)[J]. 华南师范大学学报(自然科学版), 2016, 48(6): 99-105.
引用本文: Lina Abdullah Alshahrani, LI Xi, 南俊民, 谭娟娟, 顾凤龙. 修饰玻碳电极对多巴胺和尿酸的电化学检测(英文)[J]. 华南师范大学学报(自然科学版), 2016, 48(6): 99-105.
Electrochemically Determining Dopamine and Uric acid by Cu(sal-β-Ala) (3,5-DMP2)-SWCNTs Modified Glassy Carbon Electrode[J]. Journal of South China Normal University (Natural Science Edition), 2016, 48(6): 99-105.
Citation: Electrochemically Determining Dopamine and Uric acid by Cu(sal-β-Ala) (3,5-DMP2)-SWCNTs Modified Glassy Carbon Electrode[J]. Journal of South China Normal University (Natural Science Edition), 2016, 48(6): 99-105.

修饰玻碳电极对多巴胺和尿酸的电化学检测(英文)

Electrochemically Determining Dopamine and Uric acid by Cu(sal-β-Ala) (3,5-DMP2)-SWCNTs Modified Glassy Carbon Electrode

  • Abstract: Cu(sal--Ala)(3,5-DMP2) is modified on the surface of the single-walled carbon nanotubes (SWCNTs) glass carbon electrode (GCE). The modified electrode shows impressive detection ability of dopamine (DA) and uric acid (UA). The modified electrode has a good electrocatalytic effect on DA and UA. The detection linear range of Cu(sal--Ala)(3,5-DMP2) to DA is 10.00 to 210 mmol/L and the detection limit is 7.29 mol/L. While, the detection linear range of Cu(sal--Ala)(3,5-DMP2) to UA has a good linear range from 1 to 86 mmol/L and the detection limit is 1.5 mol/L. In this work Simultaneous Differential Pulse Voltammetric (DPV) is employed to determine DA and UA. DPV method with Cu(sal--Ala)(3,5-DMP2)/SWCNTs/GCE has a good sensitivity and resolution rate.

     

/

返回文章
返回